Whole House Systems
  • Drinking Water Systems
  • Replacement Filters
  • Viqua

    VIQUA-QL-410

    Viqua QL-410 Replacement UV Lamp and Quartz Sleeve for VH410

    • UV lamp and Quartz sleeve combination (o-rings included) is ideal for full system refurbish

    • Easy do it yourself replacement

    • Reduces health risks due to contaminants in water

    • Low maintenance UV system replacements

    format_list_bulleted Features & Specs
    Package Qty: 1
    Manufacturer: Viqua
    Manufacturer's Id: QL-410
    UPC: 773058111324
    Actual Size (in): 22-inches (length) x 2-inches (outside diameter)
    Operating Temperature (°F): 40 - 125
    Operating Temperature (°C): 2.2 - 40
    Brand: Viqua
    Length (in): 22 in
    Outside Diameter (in): 2 in
    Power Requirements: 60W
    Netsuite Item Type: UltraViolet Filters & Lamps
    description Instructions
    1. Close main water supply to the UV System, and then open a tap downstream of the UV System to release pressure.
    2. Disconnect main power source and allow the unit to cool for 10 minutes. Note: Ensure there is no other power source connected such as, Solenoid Junction Box.
    3. Remove the UV lamp connector and the UV lamp
    4. (SEE STEP 7-9) Re-insert the new UV lamp inside the quartz sleeve. Attach the connector to the UV lamp and note that the connector will only allow correct installation in one position. Place and tighten the UV lamp connector.
    5. Plug the unit back to the power source. Reset the end of lamp timer alarm back to 365 days.
    6. Close the downstream tap once the UV chamber is filled with water, and inspect for any leakages.
    7. (Quartz Sleeve) Remove the top retaining nut and O-ring. Remove the bottom retaining nut, Spring and loosen the O-ring to drain the water. Remove the quartz sleeve from the UV chamber.
    8. Clean the quartz sleeve with a cloth soaked in CLR, vinegar or some other mild acid and then rinse with water.
    9. Re-insert the quartz sleeve with O-ring(s), Spring, and retaining nut(s). Hand tighten the retaining nut(s), taking care not to over-tighten.
    warning_amber Contaminants Reduced
  • Bacteria
  • Cryptosporidium
  • Cysts
  • Ecoli
  • Giardia
  • Microorganisms
  • Viruses
  • filter_alt Filter Life
    Filter Life (gallons): 12 months

    The Viqua QL-410 Replacement UV Lamp and Quartz Sleeve for the VH410 kit is the ideal pairing of necessary components for situations when an overhaul of your UV system is necessary. The quartz sleeve is an important component that surrounds the UV light, protecting and preventing it from coming in contact with the water. UV light is transmitted through the quartz sleeve and purifies the water reducing the bacteria and viruses that would otherwise make it to your beverages. With use, the sleeve will accumulate minerals from the water which must be taken care of and removed about every 3 months to prevent the UV treatment from becoming less effective. Cleaning the sleeve will both help the efficacy of the system but also prolong the life of the sleeve. Once the mineral layer becomes permanent and can not be removed the sleeve needs to be replaced. The UV lamp should be replaced every twelve months to ensure the highest quality and purity of water. No need to worry about your VH410 system with the Viqua QL-410 Replacement UV Lamp, Quartz Sleeve, and replacement o-rings, order yours today!


    {"statementLink":"","footerHtml":"","hideMobile":false,"hideTrigger":false,"disableBgProcess":false,"language":"en","position":"left","leadColor":"#146ff8","triggerColor":"#146ff8","triggerRadius":"50%","triggerPositionX":"left","triggerPositionY":"bottom","triggerIcon":"people","triggerSize":"medium","triggerOffsetX":20,"triggerOffsetY":20,"mobile":{"triggerSize":"small","triggerPositionX":"left","triggerPositionY":"bottom","triggerOffsetX":10,"triggerOffsetY":10,"triggerRadius":"50%"}}