X

Save with Auto-Ship

Get the product you need, exactly when you need it, delivered right to your door. No more searching for the right part number, we've got you covered. Plus, you'll save $$ on every order and shipping is on us. Learn more

Save Money

Free Shipping*

Choose Frequency

*Free Shipping available in the contiguous US

Viqua QL-410 Replacement UV Lamp and Quartz Sleeve for VH410

SKU
VIQUA-QL-410
Price $177.00 List Price Price $252.99 Save 30%
Availability: In Stock - Free Shipping
  • UV lamp and Quartz sleeve combination (o-rings included) is ideal for full system refurbish
  • Easy do it yourself replacement
  • Reduces health risks due to contaminants in water
  • Low maintenance UV system replacements
› See more product details
  • UV lamp and Quartz sleeve combination (o-rings included) is ideal for full system refurbish
  • Easy do it yourself replacement
  • Reduces health risks due to contaminants in water
  • Low maintenance UV system replacements
The Viqua QL-410 Replacement UV Lamp and Quartz Sleeve for the VH410 kit is the ideal pairing of necessary components for situations when an overhaul of your UV system is necessary. The quartz sleeve is an important component that surrounds the UV light, protecting and preventing it from coming in contact with the water. UV light is transmitted through the quartz sleeve and purifies the water reducing the bacteria and viruses that would otherwise make it to your beverages. With use, the sleeve will accumulate minerals from the water which must be taken care of and removed about every 3 months to prevent the UV treatment from becoming less effective. Cleaning the sleeve will both help the efficacy of the system but also prolong the life of the sleeve. Once the mineral layer becomes permanent and can not be removed the sleeve needs to be replaced. The UV lamp should be replaced every twelve months to ensure the highest quality and purity of water. No need to worry about your VH410 system with the Viqua QL-410 Replacement UV Lamp, Quartz Sleeve, and replacement o-rings, order yours today!
More Information
Package Qty 1
Manufacturer's Id QL-410
UPC 773058111324
Actual Size (in) 22-inches (length) x 2-inches (outside diameter)
Outside Diameter (inches) 2
Filter Life (months) Filter's should be replaced based on usage and filter condition. Filter life is an estimation of expected performance based on typical filtration conditions.x Filter's should be replaced based on usage and filter condition. Filter life is an estimation of expected performance based on typical filtration conditions.x 12 months
Operating Temperature (°F) 40 - 125
Operating Temperature (°C) 2.2 - 40
Flow Rate (gpm) Flow rate is the volume of water that passes through a filtration system measured in gallons per minute. A filter's flow rate indicates the maximum recommened flow for optimum filter performance. x Flow rate is the volume of water that passes through a filtration system measured in gallons per minute. A filter's flow rate indicates the maximum recommened flow for optimum filter performance. x 18
Flow Rate (lpm) 70
Power Requirements The amount of energy the system will use during operation. The system must be connected to a power source capable of providing a least this amount of power.x The amount of energy the system will use during operation. The system must be connected to a power source capable of providing a least this amount of power.x 60W
Includes Replacement Lamp, Quartz Sleeve, and necessary O-rings

Reduced Contaminants

The VIQUA-QL-410 reduces the following contaminants:

  • Bacteria
  • Cryptosporidium
  • Cysts
  • E. Coli
  • Giardia
  • Microorganisms
  • Viruses

The VIQUA-QL-410 is comparable with the following part numbers

Viqua VH410
Viqua VH410-F20
Viqua VH410M

Installation Guide

Instructions

  1. Close main water supply to the UV System, and then open a tap downstream of the UV System to release pressure.
  2. Disconnect main power source and allow the unit to cool for 10 minutes. Note: Ensure there is no other power source connected such as, Solenoid Junction Box.
  3. Remove the UV lamp connector and the UV lamp
  4. (SEE STEP 7-9) Re-insert the new UV lamp inside the quartz sleeve. Attach the connector to the UV lamp and note that the connector will only allow correct installation in one position. Place and tighten the UV lamp connector.
  5. Plug the unit back to the power source. Reset the end of lamp timer alarm back to 365 days.
  6. Close the downstream tap once the UV chamber is filled with water, and inspect for any leakages.
  7. (Quartz Sleeve) Remove the top retaining nut and O-ring. Remove the bottom retaining nut, Spring and loosen the O-ring to drain the water. Remove the quartz sleeve from the UV chamber.
  8. Clean the quartz sleeve with a cloth soaked in CLR, vinegar or some other mild acid and then rinse with water.
  9. Re-insert the quartz sleeve with O-ring(s), Spring, and retaining nut(s). Hand tighten the retaining nut(s), taking care not to over-tighten.